DCTXV
1. Compatible Refrigerants: HFC-134a / HFC-1234yf;
2. Lubricants Used: PAG / POE;
3. Operating Ambient Temperature: -40℃ to 120℃;
4. Operating Principle: Controls refrigerant flow based on temperature at the sensing element and pressure on the low-pressure side;
5. Adjustment Mechanism: Adjusted via an internal regulating screw in the valve body—turning clockwise increases superheat, while turning counterclockwise decreases it;
6. Charge Type: Gas charge / Cross charge;
7. Installation Location: Evaporator assembly;
8. Installation Orientation: Must not be installed facing downward; rotation up to 90° horizontally from the downward position is permitted;
9. Valve Type: Normally Open / Normally Closed;
10. Rated Voltage: DC 12V;
11. Coil Power Consumption: ≤10W;
12. Operating Voltage Range: 9V–16V;
13. External Leakage: <2g/year @ 2.0MPa;
14. Internal Leakage (Solenoid Valve): ≤100mL/min at 10.3bar;
15. Insulation Resistance: >10MΩ for 1 minute (DC 500V);
16. Maximum Opening Pressure Differential: ≥22bar (at ambient temperature of 20.5℃ and opening voltage of 9V);